NO | Mga produkto | Cas No. | Aplikasyon | Key Quality Indicator | ||||
Kadalisayan | Isomer | Tiyak na karumihan | *Max1 | Halumigmig | ||||
1 | Fmoc-3-(2-naphthyl)-D-Ala-OH | 138774-94-4 | Karamihan sa mga produkto | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
2 | Ac-3-(2-naphthyl)-D-Ala-OH | 37440-01-0 | Karamihan sa mga produkto | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
3 | Fmoc-3-(3-pyridinyl)-D-Ala-OH | 142994-45-4 | Karamihan sa mga produkto | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
4 | Fmoc-4-chloro-D-Phe-OH | 142994-19-2 | Karamihan sa mga produkto | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
5 | Fmoc-D-Cit-OH | 200344-33-8 | Cetrorelix | ≥99.5% | ≤0.1% | ≤0.1% | ≤0.2% | ≤1.0% |
6 | Fmoc-D-Ala-OH.H2O | 79990-15-1 | Karamihan sa mga produkto | ≥99.5% | ≤0.1% | ≤0.1% | ≤0.2% | ≤6.5% |
7 | Fmoc-D-Aph(tBuCbm)-OH | 1433975-21-3 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
8 | Fmoc-D-Aph(Cbm)-OH | 324017-22-3 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
9 | Fmoc-L-Aph(L-Hor)-OH | 1253282-31-3 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
10 | Fmoc-L-Lys(iPr,Boc)-OH | 201003-48-7 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
11 | Fmoc-N-Me-Tyr(tBu)-OH | 133373-24-7 | Abarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
12 | Fmoc-D-Asn(Trt)-OH | 180570-71-2 | Abarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
13 | Fmoc-HomoArg(Et)2-OH.HCl | 1864003-26-8 | Ganirelix | ≥95.0% | ≤0.5% | ≤1.0% | ≤2.0% | ≤2.0% |
14 | Fmoc-D-HomoArg(Et)2-OH.HCl | 2098497-24-4 | Ganirelix | ≥95.0% | ≤0.5% | ≤1.0% | ≤2.0% | ≤2.0% |
15 | Fmoc-Lys(nicotinoyl)-OH | 252049-11-9 | Antide | ≥98.0% | ≤0.2% | ≤0.3% | ≤0.5% | ≤1.0% |
16 | Fmoc-D-Lys(nicotinoyl)-OH | 252049-12-0 | Antide | ≥98.0% | ≤0.2% | ≤0.3% | ≤0.5% | ≤1.0% |
* Max1 = Max Hindi Alam na Karumihan
Iba pang Tagapagpahiwatig:
- Acetic Acid: ≤0.02% (Lahat ng Produkto)
- Ethyl Acetate: ≤0.5% (Lahat ng Produkto)
- Alkohol: ≤0.5% (Lahat ng Produkto)
Ang TOC at conductivity ng pangunahing supply at return point ay pana-panahong sinusubaybayan.Ang TOC ay sinusubaybayan ng QC sa bawat linggo.Ang conductivity ay sinusubaybayan online at naitala ng purified water station operator isang beses bawat apat na oras.Ang conductivity ay sinusubaybayan sa pangunahing RO, pangalawang RO, EDI at kabuuang return point ng distribution system.Ang detalye ng purified water ay nasa lugar at umaayon sa paunang natukoy na detalye na hindi hihigit sa 1.3 µs/cm sa 25°C (USP).Para sa pangunahing supply at return point, buong pagsubok.ay ginaganap bawat linggo, para sa iba pang gamit na punto sa circulating loop, ang buong pagsubok ay isinasagawa isang beses bawat buwan.Kasama sa buong pagsubok ang mga character, pH, nitrate, nitrite, ammonia, conductivity, TOC, non-volatile substance, heavy metal, microbial limit at bacterial endotoxin.